Thermo Q Exactive Plus
Now available from KRSS, a used fully refurbished and serviced Thermo Q Exactive Plus Hybrid Quadrupole-Orbitrap Mass Spectrometer.
- Overview
- Description
- Specifications
- Find Out More
Overview
Take Quanfirmation™ to the next level. The Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap™ Mass Spectrometer introduced the revolutionary concept of Quanfirmation. The Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer takes Quanfirmation to the next level with increased performance and new options that enhance applications from confident DMPK qual/quan screening studies to characterization of intact monoclonal antibodies.
Description
Superior Quantitation
Enhanced Analysis of Intact Proteins
High-Confidence Results
For Research Use Only. Not for use in diagnostic procedures.
- Advanced quadrupole technology (AQT) improves precursor selection and transmission for more-accurate quantitation of low-abundance analytes in complex matrices
- Sophisticated data-independent acquisition (DIA) and parallel reaction monitoring (PRM) deliver reproducible quantitation with complete qualitative confidence
- An advanced active beam guide (AABG) reduces noise and extends maintenance intervals
Enhanced Analysis of Intact Proteins
- Optional intact protein mode provides superior trapping of large molecules for improved analysis of intact proteins and protein complexes
- Optional enhanced resolution ensures maximum ID confidence in top-down proteomics and lipidomics
High-Confidence Results
- HR/AM and full-scan capabilities capture all sample data, all of the time, enabling retrospective data analysis without need to re-run samples
- Resolving power up to 140,000 FWHM eliminates isobaric interferences, increasing confidence in results when analyzing samples in complex matrices
- Better than 1ppm mass accuracy in full- and all-ion fragmentation (AIF) scan modes ensures confident compound identification
- Fast scanning at 12Hz and spectral multiplexing suited to UHPLC applications
- Rapid polarity switching maximizes information obtained
- AIF and multiple dissociation techniques — in-source CID and HCD — aid in compound identification
- Mass range to 6,000 m/z enhances detection of singly charged small molecules and biomolecules
- More than four orders of magnitude intrascan dynamic range, along with femtogram-level sensitivity, allow detection of trace-level and high-abundance compounds in the same scan
For Research Use Only. Not for use in diagnostic procedures.
Specifications
| Mass Range | 50 to 6,000 m/z |
|---|---|
| Dynamic Range | >5000:1 |
| Mass Accuracy | Internal: <1ppm RMS; External: <3ppm RMS |
| Polar Switching | One full cycle in <1 sec (one full positive mode scan and one full negative mode scan at a resolution setting of 35,000) |
| Sensitivity | Full MS: 500fg Buspirone on column S/N 100:1 SIM: 50 fg Buspirone on column yields S/N 100:1 or better |
| Resolution | 140,000 at m/z 200 |
| Scan Rates | Up to 12 Hz |