NITROSource
With unique design and advanced energy saving technology at its core the market leading NITROSource nitrogen gas generator requires less compressed air to generate more nitrogen.
Together with substantially lower servicing costs, reduced downtime and a longer working life, it adds up to the most cost-efficient nitrogen supply available; significantly more affordable than traditional sources, and delivering huge savings over the lifetime of the generator.
With over 20 years experience in the market, and over 50,000 units installed globally, Parker domnick hunter is first choice for innovative and reliable gas generation technology.
-
Features
and
Benefits -
Product
Selection - Parameters
-
Weights
and
Dimensions - Demo
- Quote
Features and Benefits
- Energy saving technology
Matches compressed air flow to the nitrogen outlet flow and purity, reducing compressed air use, and saving energy and money. - Lower cost maintenance, extensive working life
The Carbon Molecular Sieve, the ’engine’ of the generator delivers nitrogen more efficiently, leading to a very long working life - and major savings on maintenance. - Five year warranty
Free through Parker extended warranty, offering the assurance of no unexpected maintenance costs and maximised factory up-time.* - Industry compliance
Food and pharmaceutical safe, in line with European statute (EIGA) and the USA Food & Drugs Administration (FDA Article 21) and Pharmacopeia compliance. - Gas quality control
− Mass Flow Controller - ensuring correct set pressure and flow
− Integral Oxygen Analyser - constantly measures gas purity
− Off-Gas-By-Pass - automatically vents off out-ofspecification gas ensuring product quality by ensuring gas quality
− Inlet and Outlet Pressure Regulation - preventing damage to the generator or application
− Electronic Control System - 100% management of all critical generator functions - Remote monitoring
Enabling connection to proprietary remote management and the generator control systems to control and track gas parameters from a central location - Easily upgradable supply
Simply add extra generators as the application requirement grows.
*Subject to terms and conditions. Please contact your local authorised Parker distributor.
Product Selection
| Performance data is based on 7 bar g air inlet pressure and 20°C - 25°C ambient temperature. Consult Parker for performance under specific conditions. | ||||||||||||||
| Nitrogen flow rate m3/hr vs Purity (Oxygen Content) | ||||||||||||||
| Model | 5ppm | 10ppm | 50ppm | 100ppm | 250ppm | 500ppm | 0.10% | 0.40% | 0.50% | 1.00% | 2.00% | 3.00% | 4.00% | 5.00% |
| N2-20P | 3.5 | 4.5 | 6.7 | 8 | 9.7 | 11.1 | 12.4 | 16.7 | 17.7 | 21.3 | 25.3 | 29.8 | 30.9 | 33.7 |
| N2-25P | 5.3 | 6.8 | 10.1 | 12 | 14.6 | 16.7 | 18.6 | 25.1 | 26.6 | 32 | 38 | 44.7 | 46.4 | 50.6 |
| N2-35P | 7 | 9 | 13.4 | 16 | 19.4 | 22.2 | 24.8 | 33.4 | 35.4 | 42.6 | 50.6 | 59.6 | 61.8 | 67.4 |
| N2-45P | 8.8 | 11.3 | 16.8 | 20 | 24.3 | 27.8 | 31 | 41.8 | 44.3 | 53.3 | 63.3 | 74.5 | 77.3 | 84.3 |
| N2-55P | 10.5 | 13.5 | 20.1 | 24 | 29.1 | 33.3 | 37.2 | 50.1 | 53.1 | 63.9 | 75.9 | 89.4 | 92.7 | 101.1 |
| N2-60P | 11.6 | 15 | 22.3 | 26.6 | 32.3 | 36.9 | 41.2 | 55.5 | 58.9 | 70.8 | 84.1 | 99.1 | 102.7 | 112.1 |
| N2-65P | 13.3 | 17.1 | 25.5 | 30.4 | 36.9 | 42.2 | 47.1 | 63.5 | 67.3 | 80.9 | 96.1 | 113.2 | 117.4 | 128.1 |
| N2-75P | 14.5 | 18.6 | 27.7 | 33.1 | 40.2 | 46 | 51.3 | 69.1 | 73.3 | 88.2 | 104.7 | 123.4 | 127.9 | 139.5 |
| N2-80P | 16.1 | 20.7 | 30.8 | 36.8 | 44.6 | 51.1 | 57 | 76.8 | 81.4 | 98 | 116.4 | 137.1 | 142.1 | 155 |
| m3 reference standard 20°C, 1013 millibar(a), 0% relative water vapour pressure. | ||||||||||||||
Parameters
| Inlet Parameters | |
| Inlet Air Quality | Inlet Air Quality ISO 8573-1: 2010 Class 2.2.2 (2.2.1 with high oil vapour content) |
| Inlet Air Pressure Range | 5-13 bar g |
| Ambient Temperature | 5-50°C |
| Humidity | 50% @ 40°C (80% @ MAX @ 31°C) |
| IP Rating | IP20 / NEMA 1 |
| Pollution Degree | 2 |
| Installation Category | II |
| Altitude | < 2000 m |
| Noise | <80 dB (A) |
| Generator Supply | 100 - 240 +/- 10% Vac 50/60Hz |
| Generator Power | 55 W |
| Fuse | 3.15 A |
| (Anti Surge (T), 250v, 5 x 20mm HBC, Breaking | |
| Capacity 1500A @ 250v, IEC 60127, UL R/C Fuse) |
| Air Inlet | G1 |
| N2 Outlet to Buffer | G1 |
| N2 Inlet from Buffer | G11/2 |
| N2 Outlet | G11/2 |
Weights and Dimensions
| Weights and Dimensions | ||||
| Model | Height (mm) | Width (mm) | Depth (mm) | Weight (Kg) |
| N2-20P | 881 | 299 | ||
| N2-25P | 1050 | 384 | ||
| N2-35P | 1219 | 469 | ||
| N2-45P | 1388 | 553 | ||
| N2-55P | 1894 | 550 | 1557 | 638 |
| N2-60P | 1726 | 722 | ||
| N2-65P | 1895 | 807 | ||
| N2-75P | 2064 | 892 | ||
| N2-80P | 2233 | 976 | ||
| Packed Weights and Dimentions | ||||
| Model | Height (mm) | Width (mm) | Depth (mm) | Weight (Kg) |
| N2-20P | 1090 | 398.4 | ||
| N2-25P | 729 | 1260 | 495.4 | |
| N2-35P | 1430 | 580.4 | ||
| N2-45P | 1600 | 686.4 | ||
| N2-55P | 2000 | 1770 | 782.4 | |
| N2-60P | 1935 | 897.4 | ||
| N2-65P | 832 | 2100 | 997.4 | |
| N2-75P | 2275 | 1093.4 | ||
| N2-80P | 2445 | 1186.4 | ||