Maximus Lite Series

  • Benefits
    and
    Savings
  • Standard
    Features
  • Air
    Type
  • Technical
    Specifications
  • Dimensions
    and
    Weights
  • Demo
  • Quote

Benefits and Savings

Economy saving

  • Quick return on investment < 1 year
  • After installation, the generator require minimal attention and Maintenance

Reliability and safety of use

  • Nitrogen produced at low pressure and ambient temperature removes the hazards associated with high pressure cylinders and liquid Dewar’s.
  • Nitrogen available on request 24H per day ensuring the walk of the process in a regular and uninterrupted way

Compact design and flexible modular option
The system demands less floor space

Standard Features

  • Varying flow rates and purities
    HMI touch screen
    O2 display and alarm
    Air inlet dewpoint display and alarm
    Maintenance indication
    Visual and audible alarm
    Analogue connections
    Ethernet output via RJ45 connection
    IP address for remote access via internet connection

Quick and easy maintenance:

  • Access from front, no rear access required
  • Automatic economy mode
  • Option: Hazardous area version

Air Type

The nitrogen generator operate on the Pressure Swing Adsorption (PSA).

This technique uses pairs of extruded aluminium columns, filled with carbon molecular sieve (CMS).

Pre-treated compressed air enters the bottom of the one line bed and flows up through the CMS. Oxygen and other trace gases are preferentially adsorbed by the CMS, allowing nitrogen to pass through. After a pre-set time when the on-line bed is almost saturated with adsorbed gases, the system automatically switches the bed to regenerative mode, venting the contaminants from the CMS. The second CMS bed then comes on-line and takes over the separation process. The pair of beds switches
between separation and regeneration modes to ensure continuous nitrogen production.

Technical Specifications

Nitrogen outlet flo rate NL/min vs Oxygen Concentration

MODEL

10ppm

100ppm

0.1%

0.5%

1.0%

2.0%

3.0%

4.0%

5.0%

MNG102L

10.0

20.0

30.0

45.0

50.0

70.0

85.0

-

-

MNG104L

20.0

40.0

60.0

90.0

100.0

140.0

170.0

-

-

MNG106L

30.0

60.0

90.0

135.0

150.0

210.0

255.0

-

-

Air/N2 ratio

10.8

5.9

3.6

3.4

2.8

2.6

2.4

2.2

2.1

Dimensions and Weights

Inlet/outlet connections
Ambient Temp range 5-45°C
Air Inlet Pressure 6 - 16 Barg
Nitrogen Outlet Pressure* 5 - 14 Barg
Air Inlet Quality Requirement Dew point: -40°C (-40°F)
Partice: <0.1 micron
Oil : <0.01 mg/m³
Electrical Supply 90-264 VAC/ 1ph / 50-60Hz
POWER 0.2KW
Signal outlet / monitoring no volt alarm & RS232
G ½; (BSP) F
Air inlet pressure in barg 7.5 8 8.5 9 9.5
Correction factor 1.14 1.21 1.29 1.36 1.43